Copper Development Association European Copper in Architecture logo
Home


Gate valveelectric valve valve company manual valvevalves buy valvebutterfly valve high pressure valve Globe valvevalve actuator motorized valveball valvepressure valve Check valvereturn valve
Search
Online enquiry
Go to online enquiry form

 

Architecture > Detailing        

Double-lock Standing Seam Details

The details illustrated will meet most conditions likely to be encountered but the principles shown should help with any unusual situations. Drawings are extracted from the 120 page publication Copper Roofing - In Detail. This also includes tables and other information needed to design and install fully supported sheet copper roofing in accordance with current good practice.

Longitudinal Joints
Fig 1 Hand-formed double-lock standing seam open pdf
Fig 2 Roll-formed profile trays open pdf

Seam Ends
Fig 3 Turned-down standing seam end open pdf
Fig 4 Concave-form seam end open pdf
Fig 5 Chamfer-form seam end open pdf
Fig 6 Square-form seam end open pdf

'Tall' Upstands
Fig 7 Sweep standing seam upstand open pdf
Fig 8 Pinched seam upstand open pdf

'Short' Upstands
Fig 9 Standard straight dog-eared upstand open pdf
Fig 10 Pre-formed straight dog-eared upstand open pdf
Fig 11 Turned-down seam upstand open pdf

Horizontal Abutments
Fig 12 Pinched seam upstand against horizontal abutment open pdf
Fig 13 Pinched seam ventilated upstand against horizontal abutment open pdf

Lateral Joints
Fig 14 Double-lock standing seam junction with hand-formed double-lock cross welt open pdf
Fig 15 Double-lock standing seam junction with pre-formed double-lock cross welt open pdf
Fig 16 Double-lock standing seam junction with drip-step open pdf
Fig 17 Double-lock standing seam junction with lap-lock cross welt open pdf

Corners
Fig 18 Double-lock standing seam at external corners open pdf

Ridges and Hips
Fig 19 Double-lock standing seam to batten ridge or hip open pdf
Fig 20 Double-lock standing seam to ventilation ridge open pdf
Fig 21 Double-lock standing seam to T-seam ridge open pdf
Fig 22 Double-lock standing seam to standing seam ridge open pdf
Fig 23 Double-lock standing seam to ventilated monopitch roof over direct-fixed cladding open pdf

Verges
Fig 24 Double-lock standing seam with batten verge over direct-fixed cladding open pdf
Fig 25 Double-lock standing seam with standing seam verge over brickwork open pdf

Eaves
Fig 26 Double-lock standing seam at eaves with roof pitch up to 20 degrees open pdf
Fig 27 Double-lock standing seam at eaves with alternative fixing plate for eaves strip open pdf
Fig 28 Double-lock standing seam at eaves with roof pitch at and over 20 degrees open pdf
Fig 29 Double-lock standing seam at eaves above direct-fixed cladding open pdf

Pitched Valleys
Fig 30 Double-lock standing seam at recessed pitch valley gutter open pdf
Fig 31 Double-lock standing seam at pitched valley with tilting fillets open pdf
Fig 32 Double-lock standing seam at pitched valley with standing seam edges open pdf
Fig 33 Double-lock standing seam at pitched valley with lap-lock to gutter lining open pdf
Fig 34 Double-lock standing seam with pitched valley single-lock welted to roofing sheets open pdf
Fig 35 Ventilation hood open pdf

HomeAntimicrobial  |  Architecture  |  Brass  |  Electrical  | Plumbing  |  Alloys  |  Applications  |  Education  |
Environment   |  Health  |  Markets  |  Resources  |  What's New  |  About CDA  |  Contact  |  Links  |

Copper Development Association · 5 Grovelands Business Centre · Boundary Way · Hemel Hempstead · HP2 7TE· United Kingdom
Email: helpline@copperdev.co.uk  ·  Fax: +44 (0)1442 275716

Please read the disclaimer and copyright notice before you make use of any information from this site.  
© 2012 Copper Development Association